GloMax®-Multi Jr Single Tube Multimode Reader A modular single tube multimode reader for luminescence, fluorescence, and absorbance Life Science applications. | ||||||||||||||||||||||
|
E6070 Base Instrument
E6080 Instrument with Luminescence Module Fluorescence Modules: E6071 Blue E6072 UV E6073 Green E6074 Red E6075 UV-GFP Absorbance: E6076 Absorbance Module E6077 560nm Filter E6078 600nm Filter E6079 750nm Filter
| The GloMax®-Multi Jr replaces the Turner BioSystems Modulus Single Tube Multimode Reader. Same instrument... new look! If you need higher throughput in your research, see our GloMax®-Multi+ Multimode Microplate Reader.Overview The GloMax®-Multi Jr Single Tube Multimode Reader is
designed to provide the utmost flexibility. In addition to high
performance, Performance The GloMax®-Multi Jr combines the superior
performance expected from single-mode instruments with the functionality
of Ease of Use The GloMax®-Multi Jr is designed to be put into use
straight from the box without the need for special training. To achieve
this plug-and-play usability, the GloMax®-Multi Jr combines a color
touch screen with an intuitive user interface. The interface makes
running Affordable Modularity The GloMax®-Multi Jr is a modular instrument that
fits easily into most budgets. Purchase the technology or modes that you
need
Minicell Adapter For fluorescence measurements of sample volumes between 100 μl
and 200 μl, a minicell adapter is
available as an optional accessory. Lid Start Adjust settings to start measurement immediately after the lid is closed. Sample Formats For luminescence measurements, the GloMax®- Multi Jr accepts 1.5-ml microcentrifuge tubes. For fluorescence and absorbance measurements, the GloMax®-Multi Jr accepts standard 10 x 10 mm cuvettes. Touchscreen The touch screen allows simple navigation to set parameters, set calibrations, and start runs. Troubleshooting Easy access to HELP with the touch of a button. Data Handling The GloMax®-Multi Jr stores up to 18 calibrations. Data from the last 20 measurements are displayed on the color LCD screen. Optional accessories for easy data exportation include spreadsheet Interface software or a thermal printer.
Intuitive User Interface Luminescence Choose from pre-loaded Promega protocols, saved protocols, or create your own custom protocol. Use the Instrument Control screen to edit parameters, then press MEASURE LUMINESCENCE. Fluorescence The GloMax®-Multi Jr can operate in raw fluorescence mode, or touch calibrate to create a new calibration or run a previously saved calibration. Absorbance For absorbance measurements, insert a blank control and press BLANK. Based on what you've selected on the touch screen, absorbance data is presented in either percent of transmission or absorbance units. Luminescence Applications • Luciferase Assays The GloMax®-Multi Jr with a Luminescence Module is designed to deliver
performance equivalent to dedicated single-tube
luminometers while also offering the flexibility of a multi mode
reader. To achieve sensitivity on par with that of a dedicated luminometer, the luminescence channel is separated from other
measurement technologies and positioned directly below the
sample well. These conditions maximize light capture for the best
possible sensitivity. In addition, a low-noise photomultiplier tube
ensures that collected light is not compromised. The GloMax®-Multi Jr
also has greater than 5 logs of dynamic range. This dynamic
range is more than adequate to cover common luminescence applications,
thus reducing the need to dilute samples. Fluorescence Applications • DNA/RNA Quantitation
The GloMax®-Multi Jr as a fluorometer utilizes four easily exchangeable modules to measure the most popular fluorophores. In addition, custom modules can be made for non-standard applications.
Absorbance Applications • Protein Quantitation
The GloMax®-Multi Jr with the Absorbance Module provides measurements that are highly sensitive and cover a wide dynamic range. Because the optics are not shared with any other detection technology, the focused absorbance measurements yield outstanding performance. The absorbance channel has a large reading range of 0 - 4 OD with an accuracy that deviates less than 0.7%. The GloMax®-Multi Jr has three factory available filter paddles with filters for measuring 560, 600, and 750 nm. These filters accommodate the most common protein assays. Filter paddles can be easily exchanged in seconds. In addition, custom filter paddles can be readily made for non-standard applications. Specifications Available Detection Modes: Luminescence, Fluorescence, Absorbance Luminescence Module Specifications (Factory Installed) Detector: Photomultiplier tube (PMT) Fluorescence Module Specifications (User Installable) Light Source: Wavelength-matched LED Absorbance Module Specifications (User Installable) Light Source: LED
|
| ||||||||||||||||||||
| Promega Corporation Sunnyvale Office • Detection Instruments 645 N Mary Avenue • Sunnyvale CA 94085 Phone: 408.636.2400 - Toll Free: 888.636.2401 - Fax: 408.737.7919 |
||
|
||